Vertiq 81-08 85Kv

MF 3218 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g / W)
2.0 48.4 0.0 0 140 0.01 60.2% 10 45.4
4.0 48.4 0.0 2 290 0.04 71.7% 70 46.0
6.0 48.4 0.1 4 430 0.08 80.7% 170 37.9
8.0 48.4 0.2 10 560 0.14 84.7% 320 32.0
10.0 48.4 0.4 18 700 0.22 87.4% 510 27.9
12.0 48.4 0.6 30 830 0.30 87.9% 720 24.0
14.0 48.4 1.0 46 960 0.40 88.2% 990 21.5
16.0 48.3 1.4 67 1100 0.52 88.7% 1300 19.3
18.0 48.3 2.0 94 1230 0.65 88.7% 1640 17.4
20.0 48.3 2.7 130 1370 0.81 88.7% 2050 15.8
22.0 48.2 3.5 168 1500 0.95 88.5% 2420 14.4
24.0 48.2 4.5 217 1620 1.12 87.9% 2870 13.2
26.0 48.1 5.6 271 1750 1.30 87.7% 3360 12.4
28.0 48.0 6.8 327 1860 1.46 87.0% 3750 11.5
30.0 48.0 8.1 391 1970 1.63 86.2% 4250 10.9
32.0 47.9 9.6 458 2070 1.80 85.2% 4680 10.2
34.0 47.8 11.1 531 2170 1.97 84.5% 5170 9.7
36.0 47.7 12.7 604 2260 2.13 83.3% 5580 9.2
38.0 47.7 14.4 687 2340 2.29 81.7% 6000 8.7

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.