Vertiq 81-08 85Kv

MF 3016 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g / W)
2 48.4 0 0 140 0.01 38.7% 20 75.1
4 48.4 0 1 290 0.03 66.2% 70 49.4
6 48.4 0.1 4 440 0.08 101.8% 120 31.4
8 48.4 0.2 9 580 0.13 94.6% 270 31.3
10 48.3 0.3 16 710 0.2 92.3% 440 27.5
12 48.3 0.5 26 850 0.27 91.5% 640 24.2
14 48.3 0.8 40 980 0.36 90.5% 870 21.6
16 48.3 1.2 59 1120 0.46 90.4% 1150 19.4
18 48.3 1.7 84 1260 0.57 89.8% 1460 17.5
20 48.2 2.4 115 1400 0.7 89.4% 1810 15.8
22 48.2 3.1 151 1530 0.83 88.8% 2190 14.5
24 48.1 4.1 196 1670 0.99 88.4% 2600 13.3
26 48.1 5 241 1800 1.13 88.6% 3000 12.5
28 48 6.1 294 1920 1.29 88.1% 3410 11.6
30 47.9 7.3 350 2030 1.44 87.6% 3840 11
32 47.8 8.6 411 2140 1.6 87.0% 4270 10.4
34 47.8 10.1 480 2240 1.76 86.1% 4710 9.8
36 47.7 11.4 546 2340 1.9 85.3% 5090 9.3
38 47.6 13 618 2430 2.05 84.3% 5490 8.9
40 47.5 14.7 698 2520 2.2 83.3% 5890 8.4
42 47.4 16.4 779 2610 2.34 82.2% 6310 8.1

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.