Vertiq 81-08 85Kv

FA 36.2x11.8 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g / W)
2 48.4 0 0 140 0.01 62.4% 20 58.4
4 48.4 0 2 290 0.06 84.5% 110 53.2
6 48.4 0.1 6 420 0.12 87.5% 260 41.8
8 48.4 0.3 14 550 0.22 88.9% 470 33.6
10 48.4 0.5 25 680 0.32 88.5% 730 28.7
12 48.4 0.9 42 810 0.44 88.4% 1030 24.4
14 48.3 1.4 67 950 0.6 88.5% 1420 21.2
16 48.3 2 97 1070 0.76 87.3% 1820 18.7
18 48.3 2.8 137 1200 0.94 86.4% 2310 16.8
20 48.2 3.8 185 1330 1.14 86.2% 2820 15.3
22 48.2 5 240 1440 1.35 85.0% 3350 14
24 48.1 6.2 298 1550 1.54 84.2% 3860 13
26 48 7.6 366 1650 1.76 83.0% 4400 12
28 48 9.2 440 1740 1.97 81.5% 4930 11.2
30 47.9 10.8 518 1830 2.16 80.0% 5440 10.5
32 47.8 12.6 604 1910 2.36 78.3% 5930 9.8

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.