Vertiq 81-08 85Kv

FA 34.2x11.2 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.4 0.0 0 140 0.01 49.1 20 59.5
4.0 48.4 0.0 2 290 0.04 73.3 80 45.5
6.0 48.4 0.1 5 420 0.09 81.8 200 39.3
8.0 48.4 0.2 11 560 0.16 86.7 360 32.3
10.0 48.4 0.4 20 690 0.24 87.3 560 27.7
12.0 48.4 0.7 34 820 0.34 88.0 810 24.1
14.0 48.4 1.1 51 950 0.45 88.3 1130 22.0
16.0 48.3 1.6 76 1080 0.59 88.2 1480 19.5
18.0 48.3 2.2 107 1220 0.74 88.3 1870 17.5
20.0 48.3 3.0 144 1350 0.90 88.1 2310 16.0
22.0 48.2 4.0 191 1470 1.08 87.0 2780 14.6
24.0 48.2 5.0 242 1590 1.26 86.5 3270 13.5
26.0 48.1 6.2 297 1710 1.43 86.1 3700 12.5
28.0 48.0 7.5 361 1820 1.62 85.3 4140 11.5
30.0 48.0 9.0 433 1920 1.81 84.2 4670 10.8
32.0 47.9 10.6 506 2010 1.99 82.7 5130 10.1
34.0 47.8 12.2 583 2110 2.16 81.7 5600 9.6
36.0 47.7 14.0 668 2180 2.33 79.7 6030 9.0
46.0 47.7 14.9 709 2200 2.39 77.6 6340 8.9
48.0 47.7 14.8 707 2210 2.38 77.8 6250 8.8

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.