Vertiq 81-08 150Kv

P22x6.6R 48V

Philadelphia, PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.4 0.0 0 260 0.00 29.2 20 48.8
4.0 48.4 0.0 2 520 0.02 35.9 50 21.9
6.0 48.3 0.1 6 780 0.03 47.2 120 21.0
8.0 48.3 0.2 11 1040 0.06 55.4 200 17.8
10.0 48.3 0.4 20 1300 0.09 62.6 310 15.8
12.0 48.3 0.6 31 1550 0.13 68.1 460 14.7
14.0 48.3 1.0 47 1810 0.18 73.4 660 13.9
16.0 48.3 1.4 68 2060 0.24 76.1 870 12.8
18.0 48.2 1.9 93 2320 0.31 79.5 1120 12.0
20.0 48.2 2.6 126 2570 0.38 81.3 1400 11.1
22.0 48.2 3.4 165 2820 0.46 82.9 1720 10.4
24.0 48.1 4.3 208 3060 0.55 83.8 2040 9.8
26.0 48.0 5.4 261 3310 0.64 85.3 2430 9.3
28.0 48.0 6.7 321 3540 0.74 85.8 2820 8.8
30.0 47.9 8.1 388 3780 0.85 86.3 3230 8.3
32.0 47.8 9.7 465 4000 0.96 86.6 3680 7.9
34.0 47.7 11.6 552 4230 1.08 86.8 4150 7.5
36.0 47.6 13.5 644 4450 1.20 86.9 4610 7.2
38.0 47.5 15.7 744 4670 1.33 87.1 5100 6.9
40.0 47.4 17.9 847 4870 1.44 86.7 5560 6.6
42.0 47.2 20.2 953 5050 1.56 86.3 6010 6.3
44.0 47.1 23.0 1081 5230 1.69 85.8 6510 6.0
46.0 46.8 25.7 1202 5400 1.81 85.0 6950 5.8
48.0 46.8 26.4 1233 5440 1.83 84.7 7020 5.7

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.