Vertiq 81-08 150Kv

P 21x6.3R 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g / W)
2.0 48.3 0.0 1 250 0.00 15.0% 10 20.1
4.0 48.3 0.0 2 510 0.01 33.7% 30 13.2
6.0 48.3 0.1 5 770 0.02 36.4% 80 15.0
8.0 48.2 0.2 10 1030 0.04 45.4% 150 14.8
10.0 48.2 0.4 17 1280 0.07 52.2% 240 14.2
12.0 48.2 0.5 26 1540 0.09 58.3% 360 13.7
14.0 48.2 0.8 39 1800 0.13 63.8% 520 13.4
16.0 48.2 1.1 54 2050 0.17 68.4% 700 12.9
18.0 48.2 1.5 74 2310 0.22 72.1% 900 12.2
20.0 48.1 2.0 97 2560 0.27 74.5% 1120 11.5
22.0 48.1 2.6 123 2810 0.32 77.0% 1350 11.0
24.0 48.1 3.3 156 3070 0.38 79.0% 1620 10.4
26.0 48.0 4.0 193 3320 0.45 81.0% 1910 9.9
28.0 48.0 4.9 233 3560 0.51 81.9% 2170 9.3
30.0 47.9 5.9 281 3800 0.59 82.8% 2500 8.9
32.0 47.9 6.9 331 4040 0.66 83.9% 2810 8.5
34.0 47.8 8.2 390 4280 0.74 84.6% 3160 8.1
36.0 47.7 9.6 457 4510 0.82 85.1% 3540 7.8
38.0 47.6 11.1 526 4730 0.91 85.4% 3910 7.4
40.0 47.5 12.8 608 4960 1.00 85.6% 4310 7.1
42.0 47.4 14.6 692 5180 1.09 85.6% 4710 6.8
44.0 47.3 16.5 781 5390 1.19 85.8% 5110 6.5
46.0 47.2 18.6 876 5590 1.28 85.6% 5520 6.3
48.0 47.2 19.6 923 5690 1.32 85.5% 5710 6.2

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.