Vertiq 81-08 150Kv

APC 17x7E 48V

Philadelphia PA USA | Altitude:15m | Date: 2021-11-17

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g / W)
2.0 48.3 0.0 0 260 0.00 8.6% 0 0.00
4.0 48.3 0.0 2 530 0.01 16.7% 10 5.40
6.0 48.3 0.1 4 800 0.01 26.4% 40 9.36
8.0 48.3 0.2 8 1070 0.02 34.3% 80 10.27
10.0 48.3 0.3 13 1340 0.04 41.7% 140 11.14
12.0 48.3 0.4 19 1610 0.05 47.1% 200 10.64
14.0 48.3 0.5 27 1880 0.07 51.9% 290 10.93
16.0 48.3 0.7 36 2150 0.09 56.6% 380 10.50
18.0 48.3 1.0 48 2410 0.11 60.5% 500 10.44
20.0 48.2 1.3 62 2670 0.14 64.1% 620 9.99
22.0 48.2 1.6 78 2940 0.17 67.2% 750 9.64
24.0 48.2 2.0 96 3190 0.20 69.5% 900 9.37
26.0 48.2 2.4 118 3440 0.23 71.7% 1060 9.00
28.0 48.1 3.0 143 3680 0.27 73.5% 1250 8.74
30.0 48.1 3.5 169 3920 0.31 74.8% 1410 8.35
32.0 48.0 4.1 199 4160 0.35 76.0% 1600 8.04
34.0 48.0 4.9 234 4390 0.39 77.2% 1810 7.75
36.0 48.0 5.6 269 4610 0.43 77.6% 2000 7.45
38.0 47.9 6.5 310 4840 0.48 78.5% 2220 7.17
40.0 47.9 7.3 351 5060 0.52 79.0% 2430 6.92
42.0 47.8 8.4 402 5290 0.58 79.8% 2690 6.69
44.0 47.7 9.5 453 5510 0.63 80.1% 2920 6.44
46.0 47.7 10.7 510 5720 0.68 80.3% 3170 6.22
48.0 47.6 11.2 536 5810 0.71 80.8% 3290 6.14

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.