Vertiq 81-08 220Kv

P17x5.8

Philadelphia, PA USA | 15m | 2023-04-04 | 23.1 C | 30.04 in Hg | 41.6 %

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 47.2 0.1 4 350 0.00 4.0 20 5.1
4.0 47.2 0.2 8 780 0.01 12.0 60 7.3
6.0 47.2 0.3 16 1230 0.03 21.2 120 7.7
8.0 47.2 0.6 26 1680 0.05 31.0 220 8.5
10.0 47.2 0.9 41 2140 0.07 40.1 350 8.6
12.0 47.2 1.3 61 2590 0.11 48.6 520 8.5
14.0 47.1 1.8 87 3050 0.15 55.1 710 8.2
16.0 47.1 2.6 120 3510 0.20 60.9 960 8.0
18.0 47.0 3.5 163 3980 0.26 65.4 1250 7.7
20.0 46.9 4.8 224 4490 0.33 70.2 1630 7.3
22.0 46.8 6.3 294 4980 0.42 74.0 2060 7.0
24.0 46.6 8.3 385 5500 0.51 76.8 2540 6.6
26.0 46.4 10.8 502 6050 0.62 78.9 3110 6.2
28.0 46.2 13.6 627 6560 0.73 80.4 3640 5.8
30.0 45.9 16.7 766 7030 0.85 81.6 4250 5.5
32.0 45.7 20.0 915 7480 0.96 82.4 4790 5.2
34.0 45.4 23.5 1067 7850 1.08 83.1 5370 5.0
36.0 45.1 26.9 1212 8190 1.18 83.4 5850 4.8
38.0 44.8 30.1 1349 8490 1.27 83.6 6310 4.7
40.0 44.5 33.9 1508 8750 1.38 83.6 6860 4.5
42.0 44.3 37.0 1639 9000 1.45 83.3 7220 4.4
44.0 44.0 39.6 1743 9160 1.51 83.0 7540 4.3
46.0 43.9 39.1 1717 9120 1.50 83.3 7450 4.3
48.0 43.9 38.7 1698 9120 1.48 83.2 7380 4.3

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.