Vertiq 81-08 150Kv

MEJ 24x8.1R 48V

Philadelphia PA USA | Altitude: 15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.3 0.0 1 250 0.01 33.0 20 35.4
4.0 48.3 0.1 3 510 0.03 50.8 80 27.4
6.0 48.3 0.2 8 760 0.06 61.7 180 22.9
8.0 48.3 0.3 17 1000 0.11 69.4 330 19.9
10.0 48.3 0.6 30 1250 0.17 74.5 530 17.6
12.0 48.3 1.0 50 1510 0.25 78.6 780 15.5
14.0 48.2 1.6 77 1760 0.34 81.4 1090 14.1
16.0 48.2 2.3 112 2010 0.44 83.0 1430 12.7
18.0 48.1 3.3 157 2250 0.56 84.2 1830 11.7
20.0 48.1 4.5 214 2500 0.70 85.1 2300 10.7
22.0 48.0 5.8 280 2750 0.83 85.8 2770 9.9
24.0 47.9 7.5 359 2980 0.99 86.0 3290 9.2
26.0 47.8 9.4 452 3210 1.15 85.9 3840 8.5
28.0 47.7 11.6 554 3440 1.32 85.8 4410 8.0
30.0 47.6 14.0 664 3630 1.49 85.3 4970 7.5
32.0 47.4 16.5 783 3820 1.66 84.6 5540 7.1
34.0 47.3 19.2 908 4000 1.82 83.8 6080 6.7
36.0 47.1 22.2 1043 4160 1.98 82.7 6620 6.3
38.0 46.9 25.4 1189 4320 2.14 81.2 7110 6.0
40.0 46.6 29.0 1350 4470 2.29 79.6 7640 5.7
42.0 38.9 32.0 1245 4370 2.18 80.2 7290 5.9
44.0 38.8 32.0 1242 4360 2.18 80.1 7260 5.8
46.0 38.9 32.0 1246 4370 2.18 80.0 7280 5.8
48.0 38.9 32.0 1248 4380 2.18 80.0 7270 5.8

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.